Investigation of correlation between arc voltage and arc movement
Szotkowski, Šimon ; Valenta, Jiří (referee) ; Kloc, Petr (advisor)
The electric arc burns in an ionized gas and is divided into AC and DC arc according to the power supply. The electric arc is conductive, so to turn off the electric circuit, the arc must be extinguished as soon as possible. Arc breakers are used to extinguish the arc. Arc breaker must be designed to withstand the increased pressures and temperatures caused by the arc. The purpose of the bachelor's thesis was to design and construct a arc breaker with the possibility of monitoring the movement of the arc with a high-speed camera. From the measured data, the dependence between the arc voltage and the movement of the arc root was determined by correlation analysis. Correlation analysis is used to calculate the possible existence of a dependence between two quantities with the correlation coefficient and testing.
Evaluation of a switching device behaviour during short-circuit current
Fendrych, Martin ; Dostál, Lukáš (referee) ; Valenta, Jiří (advisor)
At work, I focused on the principle of electric arc extinction in low voltage devices. I particularly focused on the issue of magnetic switches. Next, I processed by the theory site issue of contact system in magnetic switches. In the practical part of my work, I was testing modular low voltage circuit breaker type of 2B and 10B. Testing was carried out in the laboratory of switchgear. I observed the movement of the contact and electric arc, which was burned between them and conductor wall. Observation was recorded by using a high-speed camera and an oscilloscope. Of acquired waveforms, I evaluated the dynamics of contacts, electric arc length and the value of the arc voltage for different moments.
Investigation of correlation between arc voltage and arc movement
Szotkowski, Šimon ; Valenta, Jiří (referee) ; Kloc, Petr (advisor)
The electric arc burns in an ionized gas and is divided into AC and DC arc according to the power supply. The electric arc is conductive, so to turn off the electric circuit, the arc must be extinguished as soon as possible. Arc breakers are used to extinguish the arc. Arc breaker must be designed to withstand the increased pressures and temperatures caused by the arc. The purpose of the bachelor's thesis was to design and construct a arc breaker with the possibility of monitoring the movement of the arc with a high-speed camera. From the measured data, the dependence between the arc voltage and the movement of the arc root was determined by correlation analysis. Correlation analysis is used to calculate the possible existence of a dependence between two quantities with the correlation coefficient and testing.
Evaluation of a switching device behaviour during short-circuit current
Fendrych, Martin ; Dostál, Lukáš (referee) ; Valenta, Jiří (advisor)
At work, I focused on the principle of electric arc extinction in low voltage devices. I particularly focused on the issue of magnetic switches. Next, I processed by the theory site issue of contact system in magnetic switches. In the practical part of my work, I was testing modular low voltage circuit breaker type of 2B and 10B. Testing was carried out in the laboratory of switchgear. I observed the movement of the contact and electric arc, which was burned between them and conductor wall. Observation was recorded by using a high-speed camera and an oscilloscope. Of acquired waveforms, I evaluated the dynamics of contacts, electric arc length and the value of the arc voltage for different moments.